4-39. FUEL LEVEL SWITCH ASSEMBLY MAINTENANCE - cont.
C. INSTALLATION.
NOTE
If new switch (4, Figure 4-30) has electrical connector plugs (5, 9), omit step 1 below.
1. Proceed as follows if electrical connector plugs (5 and 9) need to be installed on switch (4), otherwise skip
to step 2:
a. Strip 1/8 inch insulation from five switch (4) wires and crimp male contacts (8) onto ends of wires.
b. Insert blue wire into position 1, black wire into position 2, and yellow wire into position 3 of
three-circuit connector plug (5).
c. Insert red wires into positions 1 and 2 of two-circuit electrical connector plug (9).
2.
Align mounting holes on level switch (4) with holes in gasket (7) prior to mounting into fuel tank (6).
3.
Install level switch (4) and gasket (7) into fuel tank (6). Secure using five screws (1), lockwashers (2), and
washers (3).
4.
Connect level switch electrical connector plugs (5 and 9).
5.
Close main access cover and lock in place.
4-81