TM 5-6115-627-14&P
Figure 4-4. External Fuel Line Connection.
Section Il. MOVEMENT TO A NEW WORKSITE
4-3. Dismantling for Movement. Because the power plant is designed to be mobile, a minimum amount of
effort is required to relocate to a new worksite. Procedures are as follows:
a.
b.
c.
d.
Disconnect power plant from system or equipment being powered.
Disconnect ground cables from source of ground and GROUND TERMINAL stud on switch box. Roll up
cables and store in accessory boxes.
Using slide hammer, remove ground rods. Disassemble, clean, and stow ground rods in accessory boxes.
Disconnect power plant from external fuel sources, if applicable.
Disconnect ground wires between switch box and GROUND TERMINAL studs on power units. Roll up
ground wires and store in accessory boxes.
Disconnect power cables from both power units and from switch box. Roll up cables and secure each to
roadside fender of respective power unit using straps provided.
e.
f .
4-7