TM 3-1040-280-20&P
j. Air Hose Assemblies.
REMOVAL/INSTALLATION
WARNING
Air compressor tank is pressurized to 63 psig. Bleed air from tank
before attempting maintenance or disconnecting hoses. The bleed air
may contain dirt particles. Keep face away from escaping air to avoid
possible eye injury.
a.
Set circuit breaker CB1 (1 ) on control panel to OFF.
b.
Bleed air from air compressor tank by pressing control valve (2).
c.
Disconnect air hose assembly from coupling (3) on air compressor assembly and coupling (4) on smoke
generator.
d.
Connect air hose assembly to coupling (3) on air compressor assembly and coupling (4) on smoke generator.
2-31