TB 11-6115-741-24
Tier 1 Maintenance Requirements
3.0 During repairs, a new component may be substituted as an alternative to remanufacturing or repairing
the old component.
3.0.1 Tier 1 Mandatory Part Replacement Kits. Kits can be ordered
for each generator model number
using the NSN's provided in Table 3. These kits provide all the 100% mandatory replacement parts
specified in this TB. All parts that are replace as required or replace if removed must be ordered as
necessary.
TABLE 3. Tier 1 Mandatory Part Replacement Kits
and Type
Model Number
Kit Drawing Number
Kit NSN
2 kW MTG
MEP-501A
DSCC-LC-2815-0027
2815-01-532-9526
DSCC-LC-2815-0028
2815-01-532-9525
2 kW MTG
MEP-531A
DSCC-LC-2815-0029
2815-01-532-9527
3 kW TQG
MEP-831A, 832A
DSCC-LC-2815-0030
2815-01-532-9528
5 kW TQG
MEP-802A
DSCC-LC-2815-0031
2815-01-532-9529
5 kW TQG
MEP-812A
DSCC-LC-2815-0032
2815-01-532-9531
10 kW TQG
MEP-803A
DSCC-LC-2815-0033
2815-01-532-9532
10 kW TQG
MEP-813A
DSCC-LC-2815-0034
2815-01-532-9533
15 kW TQG
MEP-804A
DSCC-LC-2815-0035
2815-01-532-9535
15 kW TQG
MEP-814A
DSCC-LC-2815-0036
2815-01-532-9537
30 kW TQG
MEP-805A
DSCC-LC-2815-0037
2815-01-532-9539
30 kW TQG
MEP-815A
DSCC-LC-2815-0038
2815-01-532-9540
60 kW TQG
MEP-806A
DSCC-LC-2815-0039
2815-01-532-9541
60 kW TQG
MEP-816A
DSCC-LC-2815-0040
2815-01-532-9542
30 kW TQG
MEP-805B, 815B
DSCC-LC-2815-0041
2815-01-532-9543
60 kW TQG
MEP-806B, 816B
DSCC-LC-2815-0042
2815-01-532-9544
5 kW Mil Std
MEP-002A
DSCC-LC-2815-0043
2815-01-532-9546
10 kW Mil Std
MEP-003A, 112A
DSCC-LC-2815-0044
2815-01-532-9550
15 kW Mil Std
MEP-004A, 103A, 113A
DSCC-LC-2815-0045
2815-01-532-9552
30 kW Mil Std
MEP-005A, 104A, 114A
DSCC-LC-2815-0046
2815-01-532-9554
60 kW Mil Std
MEP-006A, 105A, 115A
DSCC-LC-2815-0047
2815-01-532-9556
100 kW Mil Std
MEP-007B
DSCC-LC-2815-0048
2815-01-532-9558
3 kW Mil Std
MEP-016B, 701A
DSCC-LC-2815-0049
2815-01-532-9560
3 kW Mil Std
MEP-016D
DSCC-LC-2815-0050
2815-01-532-9561
3 kW Mil Std
MEP-016E
DSCC-LC-2815-0051
2815-01-532-9562
5 kW APU
MEP-952B
DSCC-LC-2815-0052
2815-01-532-9563
10 kW APU
MEP-903A, 903B, 903C
3.1 Generator
Set disassembly The generator
set shall be
disassembled as
required to
perform oil
pressure and cylinder compression or crankcase vacuum testing, the repairs identified in the technical
inspection, to inspect and clean the main alternator if required, to clean the fuel tank and control box if