TM 9-6115-730-24
0091
REMOVAL
1. Ensure generator set is fully stopped, ENGINE CONTROL switch is OFF, Battery Disconnect Switch is OFF,
and DEAD CRANK SWITCH is OFF before proceeding.
2. Open battery access doors, right front doors, and left front door.
3. Use suitable container and drain cooling system (see WP 0064).
4. Remove hose clamp (Figure 1, Item 1) and disconnect hose (Figure 1, Item 2) from shutoff valve (Figure 1,
5. Remove hose clamp (Figure 1, Item 4) and disconnect hose (Figure 1, Item 2) from hose mender fitting
(Figure 1, Item 5) at top of heater (Figure 1, Item 6), and remove hose (Figure 1, Item 2).
6. Remove two hose clamps (Figure 1, Item 7), hose mender fitting (Figure 1, Item 5), and 90-degree hose
elbow (Figure 1, Item 8) from heater (Figure 1, Item 6).
7. Remove hose clamp (Figure 1, Item 9) and disconnect hose (Figure 1, Item 10) from shutoff valve (Figure 1,
8. Disconnect and remove hose clamp (Figure 1, Item 12) and disconnect hose (Figure 1, Item 10) from bottom
of heater (Figure 1, Item 6), and remove hose (Figure 1, Item 10).
9. Remove screw (Figure 1, Item 13), lockwasher (Figure 1, Item 14), and clamp (Figure 1, Item 15).
10. Remove hose clamp (Figure 1, Item 16) and disconnect low-pressure hose (Figure 1, Item 17) from IN side of
fuel metering pump (Figure 1, Item 18).
11. Disconnect and remove hose clamp (Figure 1, Item 19) and disconnect low-pressure hose (Figure 1, Item 17)
from nose fitting (Figure 1, Item 20) on left side of fuel tank, and remove hose (Figure 1, Item 17).
12. Remove two hose clamps (Figure 1, Item 21) and remove flexible braided leak-off hose (Figure 1, Item 22)
from OUT side of fuel filter (Figure 1, Item 18) and from bottom of heater (Figure 1, Item 6).
13. Remove hose clamp (Figure 1, Item 23) and disconnect flexible exhaust tubing (Figure 1, Item 24) from
heater (Figure 1, Item 6) and from heater exhaust adapter (Figure 1, Item 25).
14. Remove four screws (Figure 1, Item 26), lockwashers (Figure 1, Item 27), washers (Figure 1, Item 28), and
heater exhaust adapter (Figure 1, Item 25) from skid base.
15. Remove shutoff valve (Figure 1, Item 11) and shutoff valve (Figure 1, Item 3).
END OF TASK
INSTALLATION
NOTE
Apply sealing compound to all male pipe threads before connecting.
1. Install shutoff valve (Figure 1, Item 11) and shutoff valve (Figure 1, Item 3).
0091-2