TM 9-6115-730-24
0079
FILTER INSTALLATION AND OIL FILL - Continued
7. Check dipstick (Figure 1, Item 8) for correct oil level.
8. Set Battery Disconnect Switch to ON. Set DEAD CRANK SWITCH to NORMAL. On EMCP set ENGINE
CONTROL switch to COOL DOWN/STOP.
9. Reset CATSW2 (RESET SW OIL) switch inside left rear door.
WARNING
Operating the generator set with any access door open exposes personnel to a high noise level.
Hearing protection must be worn when operating or working near the generator set with any
access door open. Failure to comply can cause hearing damage to personnel.
10. Operate engine and check for leaks.
11. Check dipstick for correct oil level.
12. Close right front doors and left front door.
END OF TASK
OIL SAMPLING
CAUTION
Do not sample oil when engine is cold. When engine is cold, oil contaminants are not suspended
in the oil and a true representative sample of the oil will not be obtained. This may cause
equipment damage.
NOTE
Oil sampling is performed in accordance with AOAP requirements and processes.
1. Allow engine to cool for approximately 10 minutes.
2. Ensure generator set is fully stopped, ENGINE CONTROL switch is OFF/RESET, Battery Disconnect Switch
is OFF, and DEAD CRANK SWITCH is OFF before proceeding.
3. Open right front door assembly.
4. Open oil drain valve (Figure 1, Item 9) on right side of engine below oil filter, collect oil sample, and close
drain valve.
5. Close right front door assembly (latch).
END OF TASK
END OF WORK PACKAGE
0079-4