TM 9-6115-730-24
0077
REMOVAL
1. Ensure generator set is fully stopped, ENGINE CONTROL switch is OFF/RESET, Battery Disconnect Switch is
OFF, and DEAD CRANK SWITCH is OFF before proceeding.
2. Open right front doors.
3. Note routing of alternator belts (Figure 1, Item 1).
4. Turn nut (Figure 1, Item 2) CCW to relieve tension on alternator belts (Figure 1, Item 1) and slip belt (Figure 1,
WARNING
Support alternator when removing attaching hardware or alternator may fall. Failure to comply
can cause injury to personnel and equipment damage.
5. While supporting alternator (Figure 1, Item 4), remove nut (Figure 1, Item 5), two washers (Figure 1, Item 6),
and bolt (Figure 1, Item 7).
6. Remove bolt (Figure 1, Item 8), washer (Figure 1, Item 9), and rod (Figure 1, Item 10).
7. Remove nut (Figure 1, Item 11), two washers (Figure 1, Item 12), block (Figure 1, Item 13), and nut (Figure 1,
Item 2) from rod (Figure 1, Item 10).
END OF TASK
INSTALLATION
1. Install nut (Figure 1, Item 2), block (Figure 1, Item 13), two washers (Figure 1, Item 12), and nut (Figure 1,
Item 11) on rod (Figure 1, Item 10).
2. Install rod (Figure 1, Item 10) and secure with washer (Figure 1, Item 9) and bolt (Figure 1, Item 8). Tighten
bolt.
WARNING
Support alternator when removing attaching hardware or alternator may fall. Failure to comply
can cause injury to personnel and equipment damage.
3. Support alternator (Figure 1, Item 4) in place and install block (Figure 1, Item 13) over alternator mounting hole
and install bolt (Figure 1, Item 7), two washers (Figure 1, Item 6), and nut (Figure 1, Item 5). Tighten nut.
4. Slip alternator belts (Figure 1, Item 1) over pulleys and tighten nut (Figure 1, Item 2) CW to tighten belt.
7. Close right front doors.
0077-2