TM 9-6115-730-24
0055
INSTALLATION
NOTE
Install tiedown straps as required.
1. Install fuseholder (Figure 1, Sheet 1, Item 58), two screws (Figure 1, Sheet 1, Item 57), two nuts (Figure 1,
Sheet 1, Item 56), and three fuses F1, F2, and F3 (Figure 1, Sheet 1, Item 55).
2. To install CB5, CB4, and CB2 circuit breaker brackets (Figure 1, Sheet 2, Item 51), install bracket, two
washers (Figure 1, Sheet 2, Item 54), lockwashers (Figure 1, Sheet 2, Item 53), and screws (Figure 1, Sheet
2, Item 52).
3. To install any of three circuit breakers CB2 (Figure 1, Sheet 2, Item 47), CB4 (Figure 1, Sheet 2, Item 46), or
CB5 (Figure 1, Sheet 2, Item 45), install circuit breaker, two washers (Figure 1, Sheet 2, Item 50),
lockwashers (Figure 1, Sheet 2, Item 49), and screws (Figure 1, Sheet 2, Item 48). Connect wires as tagged.
4. To install diode D1 (Figure 1, Sheet 2, Item 39), install diode, nut (Figure 1, Sheet 2, Item 44), insulator
(Figure 1, Sheet 2, Item 43). Install diode and insulator with two washers (Figure 1, Sheet 2, Item 42),
lockwashers (Figure 1, Sheet 2, Item 41), and screws (Figure 1, Sheet 2, Item 40). Connect wires as tagged.
5. To install ammeter shunt R4 (Figure 1, Sheet 2, Item 37), install shunt and two screws (Figure 1, Sheet 2,
Item 38). Connect wires as tagged.
6. To install relay mounting track (Figure 1, Sheet 1, Item 33), install track, two screws (Figure 1, Sheet 1,
Item 34), lockwashers (Figure 1, Sheet 1, Item 35), and washers (Figure 1, Sheet 1, Item 36).
7. To install any spare fuseholder (Figure 1, Sheet 1, Item 28), install fuseholder (Figure 1, Sheet 1, Item 28),
two insulators (Figure 1, Sheet 1, Item 31), clips (Figure 1, Sheet 1, Item 32), washers (Figure 1, Sheet 1,
Item 30), and two screws (Figure 1, Sheet 1, Item 29). Connect wires as tagged. To install any of three spare
fuses (Figure 1, Sheet 1, Item 27), push fuse into fuseholder (Figure 1, Sheet 1, Item 28).
8. To install starter motor magnetic switch (SMMS) relay (Figure 1, Sheet 1, Item 23), install SMMS relay, two
lockwashers (Figure 1, Sheet 1, Item 26), washers (Figure 1, Sheet 1, Item 25), and two screws (Figure 1,
Sheet 1, Item 24). Connect wires as tagged.
9. To install relay SRY (Figure 1, Sheet 1, Item 19), install relay, lockwasher (Figure 1, Sheet 1, Item 22),
washer (Figure 1, Sheet 1, Item 21), and screw (Figure 1, Sheet 1, Item 20). Connect wires as tagged.
10. To install either switch CATSW2 (Figure 1, Sheet 1, Item 16), or CATSW1 (Figure 1, Sheet 1, Item 15), install
switch, lockwasher (Figure 1, Sheet 1, Item 18), and nut (Figure 1, Sheet 1, Item 17). Connect wires as
tagged.
11. To install terminal board TB5 (Figure 1, Sheet 1, Item 11), install marker strip (Figure 1, Sheet 1, Item 14),
terminal board, two screws (Figure 1, Sheet 1, Item 13) and nuts (Figure 1, Sheet 1, Item 12). Connect wires
as tagged.
12. Install switch plate (Figure 1, Sheet 1, Item 9) on air cleaner bracket (Figure 1, Sheet 1, Item 10) and secure
with two screws (Figure 1, Sheet 1, Item 8), washers (Figure 1, Sheet 1, Item 7), and lockwashers (Figure 1,
Sheet 1, Item 6). Install dead crank plate (Figure 1, Sheet 1, Item 5) and secure with two rivets (Figure 1,
Sheet 1, Item 4).