0054
REMOVAL
1. Ensure generator set is fully stopped, ENGINE CONTROL switch is OFF/RESET, Battery Disconnect Switch
is OFF, and DEAD CRANK SWITCH is OFF before proceeding.
2. Ensure there is no external cable connected to slave receptacle.
3. Open battery access doors. Open left front door.
NOTE
When looking into battery compartment, batteries are identified from left to right as BT4, BT2,
BT1, and BT3.
Cut tiedown straps as required.
4. Tag and disconnect battery cable 1A40 (Figure 1, Item 1) from battery BT2 negative terminal (Figure 1,
Item 2).
5. Tag and disconnect battery cable 1D40 (Figure 1, Item 3) from battery BT4 negative terminal (Figure 1,
Item 4).
6. Tag and disconnect battery cable 24H40 (Figure 1, Item 5) from battery BT3 positive terminal (Figure 1,
Item 6).
7. Remove four nuts (Figure 1, Item 7), screws (Figure 1, Item 8), washers (Figure 1, Item 9), and slave
receptacle (Figure 1, Item 10) out of TQG.
8. Tag and disconnect battery cables 1D40 (Figure 1, Item 3) and 24H40 (Figure 1, Item 5) from slave
receptacle (Figure 1, Item 10).
9. Remove eight locknuts (Figure 1, Item 11), washers (Figure 1, Item 12), screws (Figure 1, Item 13) and
pocket (Figure 1, Item 14).
INSTALLATION
NOTE
Install tiedown straps as required.
1. Install pocket (Figure 1, Item 14), eight screws (Figure 1, Item 13), washers (Figure 1, Item 12), and locknuts
(Figure 1, Item 11).
2. Remove tags and connect battery cables 1D40 (Figure 1, Item 3) and 24H40 (Figure 1, Item 5) to slave
receptacle (Figure 1, Item 10).
3. Install slave receptacle (Figure 1, Item 10) with four washers (Figure 1, Item 9), screws (Figure 1, Item 8), and
nuts (Figure 1, Item 7).
0054-2