TM 9-6115-730-24
0009
TROUBLESHOOTING USING GSC FAULT CODES - Continued
CORRECTIVE ACTION - Continued
STEP 6.
Set Battery Disconnect Switch to ON. Set DEAD CRANK SWITCH to NORMAL.
Turn ENGINE CONTROL switch to MANUAL START.
NOTE
Measurement must be made before the total cycle crank time of 90 seconds (setpoint P017
STEP 7.
Quickly measure resistance between A1-6 and A1-18. If resistance not less than
5 ohms or if resistance not greater than 5,000 ohms, measured in STEP 5, check
all GSC fuses (FO-4, Sheets 3 and 5). If GSC fuses are ok, replace GSC
STEP 8.
Turn the ENGINE CONTROL switch to OFF/RESET. Battery Disconnect Switch
is OFF; DEAD CRANK SWITCH is OFF.
STEP 9.
Reinstall fuse A1F4 and reconnect wire(s) to GSC A1-18.
STEP 10.
Verify the problem has been resolved.
0009-41