TM 9-6115-730-24
0002
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS - Continued
GENERATOR HOUSING
The housing (Figure 1, Sheet 6, Item 35) is fabricated from sheet steel and attaches directly to mating flanges on
the skid base. The housing is thus removable for unscheduled maintenance and engine or generator removal.
Access openings and doors (Figure 1, Sheet 6, Item 36) allow engine, generator, and other component servicing.
Each side of the rear housing has a set of double doors and the large doors at the front of the housing provide
accessibility. The housing structure incorporates acoustic damping foam and internal baffle structures to reduce
engine noise. The rugged design of the housing includes reinforced corners and access openings to meet
transportability, operational, and handling requirements of a mobile military generator set.
TRAILER-MOUNTED CONFIGURATION (PU-809A)
The skid-mounted TQG can be mounted on a model XM1061 E1 5-ton trailer (Figure 1, Sheet 6, Item 37). In this
configuration, the TQG can be towed and positioned as required. In the power-unit configuration, the trailer-
mounted TQG has an accessory box (Figure 1, Sheet 6, Item 38) and two fire extinguishers (Figure 1, Sheet 6,
Item 39). The TQG skid is bolted directly to the trailer bed and frame.
EQUIPMENT DATA
Table 1 lists equipment data for the 200 kW TQG.
Table 1. 200 kW TQG Equipment Data.
EQUIPMENT
DATA
200 kW Tactical Quiet Generator Set
MEP-809A /PU-809A
Overall length
114 in. (290 cm)
50 in. (127 cm)
Width
75 in. (191 cm)
Height
Weight
9,300 lb (4218 kg)
Wet (includes fuel)
8,200 lb (3719 kg)
Dry
Engine
Manufacturer
Caterpillar
Model
C-12, serial number BCY series
Type
Six cylinder, in-line, four cycle, turbocharged diesel
395 hp @ 1800 rpm (60 Hz)
329 hp @ 1500 rpm (50 Hz)
732 cu. in (12.0L)
Displacement
Valves per cylinder
Inlet: 0.015 in. (0.38 mm)
Valve lash setting (cold engine)
Cooling system
Type
Pressurized radiator and coolant pump
42 qt (39.7L)
Capacity
170F to 200F (77C to 93C)
Normal operating temperature
24 Vdc, range programmable
Temperature indicating system voltage