TM 9-6115-730-24
0002
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS - Continued
Figure 1. 200 kW Tactical Quiet Generator Location of Components (Sheet 6 of 6).
The alternator (Figure 1, Sheet 1, Item 5) is located on the right side of the engine. The alternator maintains the
batteries in a state of full charge. The alternator also provides 24 Vdc voltage for TQG control circuits and to the
NATO slave receptacle.
RADIATOR
The radiator (Figure 1, Sheet 1, Item 6) located at the front of the TQG eliminates engine heat via circulated
coolant and air. The radiator and engine fan are the primary heat exchanger for cooling engine coolant and
turbocharged engine intake air.
WATER PUMP
The water pump (Figure 1, Sheet 1, Item 7) located on the right side of the engine circulates coolant through the
engine block and radiator to cool the engine.
0002-7