TM 9-6115-730-10
200 kW TACTICAL QUIET GENERATOR SET
0006 00
OPERATION UNDER USUAL CONDITIONS Continued
ASSEMBLY AND PREPARATION FOR USE Continued
Connecting Auxiliary Fuel Hose
WARNING
Metal jewelry can conduct electricity and become entangled in generator set components. Remove
all metal jewelry when working on generator set. Failure to comply can cause injury or death to
personnel.
WARNING
Diesel fuel is flammable and toxic to eyes, skin, and respiratory tract. Skin and eye protection are
required when working in contact with diesel fuel. Avoid repeated or prolonged contact. Provide
adequate ventilation. Operators are to wash exposed skin and change chemical soaked clothing
promptly if exposed to fuel. Failure to comply can cause injury or death to personnel.
Fuels used in the generator set are flammable. When filling the fuel tank, maintain metal-to-metal
contact between filler nozzle and fuel tank opening to eliminate static electrical discharge. Failure to
comply can result in flames and possible explosion and can cause injury or death to personnel and
damage to the generator set.
Fuels used in the generator set are flammable. Do not smoke or use open flames when performing
maintenance. Failure to comply can result in flames and possible explosion and can cause injury or
death to personnel and damage to the generator set.
NOTE
Fuel tank holds 128 gallons (485L). The following procedure is for using an external fuel source.
1.
On EMCP, set ENGINE CONTROL switch to OFF/RESET.
2.
At DIESEL FUEL fill port (16), remove protective cap and attach auxiliary fuel hose (17) to fuel connection marked
EXTERNAL FUEL SUPPLY and to external fuel source.
0006 00-8