ASSEMBLY AND PREPARATION FOR USE Continued
Installation of Ground Rod Continued
4.
Route ground cable (2) from outside to inside of housing through OUTPUT CABLES boot (8).
5.
Insert ground cable (2) through slot on ground terminal located on TQG skid frame (9).
6.
Tighten nut on terminal (9) with wrench (7).
7.
Connect coupler (5) to ground rod (1) and screw driving stud (4) into coupler (5). Make sure that driving stud is
screwed completely into coupler and contacts top of ground rod.
8.
Drive ground rod into ground until coupler is just above surface.
9.
Remove driving stud and install another section of ground rod into coupler.
10. Repeat steps 7, 8, and 9 until ground rod has been driven 8 feet or deeper. Drive ground rod down until last coupler is
just above ground surface.
11. Remove coupler (5) and driving stud (4) and return to storage inside left rear housing door.