TM 9-6115-729-24
DIRECT SUPPORT (FIELD) LEVEL MAINTENANCE
TACTICAL QUIET GENERATOR 100 kW, 50/60 Hz MEP-807A/PU-807A
ROCKER SHAFT AND PUSHRODS MAINTENANCE
INITIAL SETUP:
Tools and Special Tools
Personnel Required
Shop Equipment, Automotive Maintenance,
Two
Shop Equipment, Field Maintenance, Basic
References
TM 9-6115-729-24P
Materials/Parts
Equipment Condition
Timing bolt, P/N 4C5851
WARNINGS
Metal jewelry will conduct electricity. All jewelry can become entangled in generator set
components. Remove all jewelry when working on generator set. Failure to comply can cause
injury or death to personnel by electrocution.
DO NOT wear loose clothing when performing checks, services and maintenance. Failure to
comply can cause injury or death to personnel.
High voltage is produced when this generator set is in operation. Make sure unit is completely shut
down and free of any power source before attempting any repair or maintenance on the unit.
Failure to comply can cause injury or death to personnel.
High voltage is produced when the generator set is in operation. Never attempt to start or
maintain the generator set unless it is properly grounded. Failure to comply can cause injury or
death to personnel.
CAUTION
All fittings and openings must be capped or plugged immediately after opening to prevent
REMOVAL
1. Remove two bolts (Figure 1, Item 1) and washers (Figure 1, Item 2) from rocker shaft assembly.
2. Remove 11 bolts (Figure 1, Item 3), washers (Figure 1, Item 4), and entire rocker shaft assembly from
cylinder head (Figure 1, Item 5).
3. Remove 12 pushrods (Figure 1, Item 6) from cylinder head (Figure 1, Item 5).
0115-1