TM 9-6115-729-24
UNIT (FIELD) LEVEL MAINTENANCE
TACTICAL QUIET GENERATOR 100 kW, 50/60 Hz MEP-807A/PU-807A
THERMOSTAT HOUSING MAINTENANCE
INITIAL SETUP:
Tools and Special Tools
Materials/Parts (cont.)
Shop Equipment, Automotive Maintenance,
Thermostat (2)
Shop Equipment, Field Maintenance, Basic
Personnel Required
Materials/Parts
One
References
Breakthrough cleaning solvent (WP 0120, Item 47)
Gasket
TM 9-6115-729-24P
O-Ring
WARNINGS
Metal jewelry will conduct electricity. All jewelry can become entangled in generator set
components. Remove all jewelry when working on generator set. Failure to comply can cause
injury or death to personnel by electrocution.
DO NOT wear loose clothing when performing checks, services and maintenance. Failure to
comply can cause injury or death to personnel.
High voltage is produced when this generator set is in operation. Make sure unit is completely shut
down and free of any power source before attempting any repair or maintenance on the unit.
Failure to comply can cause injury or death to personnel.
High voltage is produced when the generator set is in operation. Never attempt to start or
maintain the generator set unless it is properly grounded. Failure to comply can cause injury or
death to personnel.
REMOVAL
1. Position suitable drain pan below thermostat housing (Figure 1, Item 1) to catch spills.
2. Loosen hose clamp (Figure 1, Item 2) and disconnect hose (Figure 1, Item 3).
3. If optional winterization kit is installed, loosen hose clamp (Figure 1, Item 4) and disconnect hose (Figure 1,
Item 5).
4. Loosen hose clamp (Figure 1, Item 6) and disconnect hose (Figure 1, Item 7).
0083-1