INSTALLATION - Continued
3. Carefully thread alternator belt (Figure 1, Item 1) over fan blades, then onto idler (Figure 1, Item 7), tensioner
pulley (Figure 1, Item 2), crankshaft pulley (Figure 1, Item 6), pulley (Figure 1, Item 5), and idler (Figure 1, Item
4).
4. Place wrench on tensioner pulley (Figure 1, Item 2) and use to rotate tensioner pulley clockwise (CW)
sufficiently to allow alternator belt (Figure 1, Item 1) to be slipped onto alternator pulley (Figure 1, Item 3).
Allow tensioner pulley (Figure 1, Item 2) to slowly rotate back into place.
5. Check alternator belt (Figure 1, Item 1) and water pump belt (Figure 1, Item 11) for correct routing and be sure
belts are firmly seated in all pulley grooves.
6. Install upper and lower right side fan guards (WP 0065).
7. Close right front door.
END OF TASK
END OF WORK PACKAGE
0073-4