TM 9-6115-729-24
0053
REMOVAL
1. Ensure generator set is fully stopped, ENGINE CONTROL switch is OFF/RESET, Battery Disconnect Switch is
OFF, and DEAD CRANK SWITCH is OFF before proceeding.
2. Ensure there is no external cable connected to slave receptacle.
3. Open right and left battery access doors. Open left front door.
NOTE
Cut tiedown straps as required.
4. Tag and disconnect battery cables 1C40 (Figure 1, Item 1) and 1A40 (Figure 1, Item 2) from left battery BT2
negative terminal (Figure 1, Item 3).
5. Tag and disconnect battery cable 12A40 (Figure 1, Item 4) from right battery BT1 negative terminal (Figure 1,
Item 5).
6. Remove four nuts (Figure 1, Item 6), screws (Figure 1, Item 7), washers (Figure 1, Item 8), retainer (Figure 1,
Item 9), and push slave receptacle (Figure 1, Item 10) out of TQG.
7. Tag and disconnect battery cables 1C40 (Figure 1, Item 1) and 24D40 (Figure 1, Item 11) from slave
receptacle (Figure 1, Item 10).
8. Remove eight locknuts (Figure 1, Item 12), washers (Figure 1, Item 13), screws (Figure 1, Item 14), and slave
receptacle pocket (Figure 1, Item 15).
END OF TASK
INSTALLATION
NOTE
Install tiedown straps as required.
1. Install slave receptacle pocket (Figure 1, Item 15), eight screws (Figure 1, Item 14), washers (Figure 1, Item
13), and locknuts (Figure 1, Item 12).
2. Remove tags and connect battery cables 1C40 (Figure 1, Item 1) and 24D40 (Figure 1, Item 11) to slave
receptacle (Figure 1, Item 10).
3. Install slave receptacle (Figure 1, Item 10) and retainer (Figure 1, Item 9) with four washers (Figure 1, Item 8),
screws (Figure 1, Item 7), and nuts (Figure 1, Item 6).
4. Remove tags and connect battery cable 12A40 (Figure 1, Item 4) to right battery BT1 negative terminal
(Figure 1, Item 5).
5. Remove tags and connect battery cables 1C40 (Figure 1, Item 1) and 1A40 (Figure 1, Item 2) to left battery
BT2 negative terminal (Figure 1, Item 3).
6. Close left front door. Close right and left battery access doors.
0053-2