TM 9-6115-729-24
0041
DISASSEMBLY - Continued
10. To remove duplex receptacle (Figure 2, Sheet 2, Item 31), remove four screws (Figure 2, Sheet 2, Item 32),
cover (Figure 2, Sheet 2, Item 33), and receptacle.
11. To remove paralleling receptacle (Figure 2, Sheet 2, Item 34), remove four nuts (Figure 2, Sheet 2, Item 35),
four screws (Figure 2, Sheet 2, Item 36), cover (Figure 2, Sheet 2, Item 37), and receptacle. Repeat for other
paralleling receptacle.
12. To remove nameplate (Figure 2, Sheet 2, Item 38), (Figure 2, Sheet 2, Item 39), or (Figure 2, Sheet 2, Item
40), remove two rivets (Figure 2, Sheet 2, Item 41) and nameplate.
13. To remove ground fault circuit interrupter GFCI (Figure 2, Sheet 3, Item 42), remove two nuts (Figure 2, Sheet
3, Item 43), screws (Figure 2, Sheet 3, Item 44), and circuit interrupter.
14. To remove AC transformer box A5 (Figure 2, Sheet 3, Item 45), remove three fuses (Figure 2, Sheet 3, Item
46), four screws (Figure 2, Sheet 3, Item 47), four lockwashers (Figure 2, Sheet 3, Item 48), four washers
(Figure 2, Sheet 3, Item 49), and AC transformer box.
15. To remove upper transformer mounting bracket (Figure 2, Sheet 3, Item 50), remove nut (Figure 2, Sheet 3,
Item 51), two screws (Figure 2, Sheet 3, Item 52), two lockwashers (Figure 2, Sheet 3, Item 53), two washers
(Figure 2, Sheet 3, Item 54), and bracket.
16. To remove lower transformer mounting bracket (Figure 2, Sheet 3, Item 55), remove nut (Figure 2, Sheet 3,
Item 56), two screws (Figure 2, Sheet 3, Item 57), two lockwashers (Figure 2, Sheet 3, Item 58), two washers
(Figure 2, Sheet 3, Item 59), and bracket.
17. To remove loop clamp (Figure 2, Sheet 3, Item 60), remove nut (Figure 2, Sheet 3, Item 61), loop clamp, nut
(Figure 2, Sheet 3, Item 61), and screw (Figure 2, Sheet 3, Item 62).
18. To remove component mounting channel (Figure 2, Sheet 3, Item 63), remove five screws (Figure 2, Sheet 3,
Item 64), lockwashers (Figure 2, Sheet 3, Item 65), washers (Figure 2, Sheet 3, Item 66), and channel.
19. Remove nut (Figure 2, Sheet 3, Item 67), two washers (Figure 2, Sheet 3, Item 68), nut, and screw (Figure 2,
Sheet 3, Item 69).
20. To remove relay KR (Figure 2, Sheet 4, Item 70), CDR (Figure 2, Sheet 4, Item 71), AFPR (Figure 2, Sheet 4,
Item 72), AR (Figure 2, Sheet 4, Item 73), GRF (Figure 2, Sheet 4, Item 74), or KFF (Figure 2, Sheet 4, Item
75), remove spring (Figure 2, Sheet 4, Item 76), relay, and socket (Figure 2, Sheet 4, Item 77).
21. To remove relay DBLO (Figure 2, Sheet 4, Item 78) or DBHI (Figure 2, Sheet 4, Item 79), remove spring
(Figure 2, Sheet 4, Item 76), relay, and socket (Figure 2, Sheet 4, Item 80).
22. To remove relay PAR (Figure 2, Sheet 4, Item 81), remove spring (Figure 2, Sheet 4, Item 76), relay, and
socket (Figure 2, Sheet 4, Item 82).
23. To remove track (Figure 2, Sheet 4, Item 83), remove two screws (Figure 2, Sheet 4, Item 84), two washers
(Figure 2, Sheet 4, Item 85), two insulator blocks (Figure 2, Sheet 4, Item 86), two clips (Figure 2, Sheet 4,
Item 87), three nuts (Figure 2, Sheet 4, Item 88), three screws (Figure 2, Sheet 4, Item 89), three washers
(Figure 2, Sheet 4, Item 90), and track.
0041-10