TM 9-6115-729-24
UNIT (FIELD) LEVEL MAINTENANCE
TACTICAL QUIET GENERATOR 100 kW, 50/60 Hz MEP-807A/PU-807A
DOOR SUPPORT ASSEMBLY MAINTENANCE
INITIAL SETUP:
Tools and Special Tools
References
Tool Kit, General Mechanic's (WP 0119, Item 1)
TM 9-6115-729-24P
Personnel Required
One
WARNINGS
Metal jewelry will conduct electricity. All jewelry can become entangled in generator set
components. Remove all jewelry when working on generator set. Failure to comply can cause
injury or death to personnel by electrocution.
DO NOT wear loose clothing when performing checks, services and maintenance. Failure to
comply can cause injury or death to personnel.
High voltage is produced when this generator set is in operation. Make sure unit is completely shut
down and free of any power source before attempting any repair or maintenance on the unit.
Failure to comply can cause injury or death to personnel.
High voltage is produced when the generator set is in operation. Never attempt to start or
maintain the generator set unless it is properly grounded. Failure to comply can cause injury or
death to personnel.
REMOVAL
1. Open load board door (Figure 1, Item 1).
2. Remove two locknuts (Figure 1, Item 2), four washers (Figure 1, Item 3), two lockwashers (Figure 1, Item 4),
and two screws (Figure 1, Item 5).
3. Remove locknut (Figure 1, Item 6), two washers (Figure 1, Item 7), spacer (Figure 1, Item 8), screw (Figure 1,
Item 9), and door support bracket (Figure 1, Item 10).
4. Remove locknut (Figure 1, Item 11), two washers (Figure 1, Item 12), spacer (Figure 1, Item 13), screw
(Figure 1, Item 14), and link (Figure 1, Item 15).
5. Remove locknut (Figure 1, Item 16), screw (Figure 1, Item 17), washer (Figure 1, Item 18), and door support
bracket (Figure 1, Item 19).
6. Remove two locknuts (Figure 1, Item 20), two screws (Figure 1, Item 21), four washers (Figure 1, Item 22),
and bracket (Figure 1, Item 23) from load board (Figure 1, Item 24).