TM 9-6115-729-24
0016
Table 1. Preventive Maintenance Checks and Services - Continued.
ITEM TO BE
CHECKED
EQUIPMENT
ITEM
MAN-
OR
NOT READY/
NO.
INTERVAL
HOUR
SERVICED
PROCEDURE
AVAILABLE IF:
TQG INTERIOR
4
Quarterly or
Control Box
Check panel gauges, switches,
Any gauges,
300 hours
Assembly
controls, decals/data plates for
switches, controls,
damage, missing parts, readability,
decals/data plates
damaged or missing
parts. Any gauges or
decals/data plates
not readable. Any
loose components.
5
Quarterly or
Reconnection
Check reconnection terminal board
Terminal board
300 hours
Terminal
for damage, rust, corrosion, missing
damaged or missing
Board
parts, and secure mounting
parts. Terminal
board cannot be
securely mounted.
6
Quarterly or
Load Terminal Check load terminal board for
Terminal board
300 hours
Board
damage, rust, corrosion, missing
damaged or missing
parts, and secure mounting
parts. Terminal
board cannot be
securely mounted.
7
Quarterly or
Battery
Check battery cables for damage,
Battery cables
300 hours
Cables
corrosion, missing parts, and secure
damaged, corroded,
mounting. Check cables for fraying,
or missing parts.
Cables cannot be
securely mounted.
8
Quarterly or
Batteries
Clean battery terminals. Check
Battery terminals
300 hours
terminals for looseness, breaks, or
loose, broken, or
damaged. Batteries
will not hold charge.
9
Quarterly or
Batteries (if
Check electrolyte level; add distilled
Electrolyte level
300 hours
lead-acid
water as required.
below top of plates.
type)
10
Quarterly or
Power Cables Check power cables for damage,
Power cables
300 hours
corrosion, missing parts, and secure
damaged, corroded,
mounting. Check cables for fraying,
or missing parts.
Cables cannot be
securely mounted.
0016-2