TM 9-6115-729-24
0013
ELECTRONIC TECHNICIAN (ET) TROUBLESHOOTING - Continued
CORRECTIVE ACTION - Continued
OPERATING RPM
DESIRED INJECTION
ACTUAL INJECTION
PERCENTAGE
PRESSURE
PRESSURE (CAT ET)
OUTPUT (CAT ET)
1
870
2
1450
3
2031
4
2611
LOW IDLE
DESIRED INJECTION
ACTUAL INJECTION
PERCENTAGE
PRESSURE
PRESSURE (CAT ET)
OUTPUT (CAT ET)
1
870
2
1450
3
2031
4
2611
n. If the injection actuation pressure output is between 65 percent and 100
percent of the DESIRED INJECTION PRESSURE, the injection actuation
pressure output is within specifications.
o. If the injection actuation pressure output is not within specifications. Proceed
to STEP 5.