TM 9-6115-729-10
100 kW TACTICAL QUIET GENERATOR SET
0007 00
OPERATION UNDER UNUSUAL CONDITIONS Continued
OPERATION UNDER RAINY OR HUMID CONDITIONS
CAUTION
Failure to remove waterproof material before operating generator set could result in equipment
damage.
1.
If possible, provide a shelter for generator set. Cover generator set with canvas or other waterproof material when it is
not being operated.
2.
Provide adequate drainage to prevent water from accumulating on operation site.
3.
Keep all generator set access doors closed, as much as possible, to prevent entry of water into housing assembly.
4.
Drain water frequently from fuel filter/water separator (WP 0016 00).
WARNING
High voltage is produced when this generator set is in operation. Make sure unit is completely shut
down and free of any power source before attempting any repair or maintenance on the unit.
Failure to comply can cause injury or death to personnel.
High voltage is produced when the generator set is in operation. Never attempt to start the
generator set unless it is properly grounded. Failure to comply can cause injury or death to
personnel.
DC voltages are present at generator set electrical components even with generator set shut down.
Avoid shorting any positive with ground/negative. Failure to comply can cause injury to personnel
and damage to equipment.
5.
Remove moisture from generator set components before and after each operating period.
6.
Keep fuel tank full to protect against moisture, condensation and accumulation of water.
END OF TASK
OPERATION IN SALT WATER AREAS
CAUTION
Failure to remove waterproof material before operating generator set could result in equipment
damage.
1.
If possible, provide a shelter for the generator set. Locate generator set so that radiator faces into prevailing winds. Use
natural barriers or, if possible, construct a barrier to protect generator set from salt water. Cover generator set with
canvas or other waterproof material when it is not being operated.
2.
Keep all generator access doors closed, as much as possible, to prevent entry of salt water into housing assembly.
3.
Wash exterior surfaces frequently with clean water when generator set is not operating.
4.
Check wiring connections for corrosion and wire insulation for signs of deterioration.
END OF TASK
0007 00-5