TM 9-6115-729-10
100 kW TACTICAL QUIET GENERATOR SET
0007 00
OPERATION UNDER UNUSUAL CONDITIONS Continued
OPERATION IN DUSTY OR SANDY CONDITIONS
1.
If possible, provide a shelter for generator set. Use available natural barriers to shield generator set from blowing dust or
sand.
2.
Keep generator set doors closed to optimize engine cooling, keep the engine clean, and reduce noise.
3.
Wet down dusty and sandy surface areas around generator set frequently if water is available.
4.
Keep all access doors closed, as much as possible, to prevent entry of dust and sand into housing assembly.
5.
Wipe dust and sand frequently from the generator set external surface and components. Wash exterior surfaces
frequently with clean water when generator set is not operating.
6.
Service engine air cleaner assembly frequently to compensate for intake of additional dust or sand (WP 0014 00).
7.
Drain sediment frequently from fuel filter/water separator. When servicing fuel tank be careful to prevent dust or sand
8.
Notify maintenance to change engine oil and oil filter frequently.
9.
Store oil and fuel in dust-free containers.
10. Ensure generator set ground connections are free of dust and sand and connections are tight before starting the unit.
END OF TASK
0007 00-4