ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
OPERATING
OPERATING
MAKE SURE
MAKE SURE
1.
SET IS GROUNDED
1.
SET IS GROUNDED
2.
TO CHECK OIL
2.
TO CHECK OIL
3.
TO CHECK FUEL LEVEL
3.
TO CHECK FUEL LEVEL
4.
LOAD CONTACTOR IS OFF
4.
LOAD CONTACTOR IS OFF
5.
LOAD IS CONNECTED
5.
LOAD IS CONNECTED
6.
ENGINE AIR INTAKE IS IN
6.
ENGINE AIR INTAKE IS IN
NORMAL POSITION
NORMAL POSITION
MANUAL START
MANUAL START
AT 23FORWARMER
AT 23F ORWARMER
1.
MOVE LEVER TO RUN
1.
MOVE LEVER TO RUN
2.
PRESS LEVER A
2.
PRESS LEVER A
3.
PULL RECOIL STARTER
3.
PULL RECOIL STARTER
4.
TURN LOAD CONTACTOR ON
4.
TURN LOAD CONTACTOR ON
ELECTRIC START
ELECTRIC START
AT ALL TEMPERATURES
AT ALL TEMPERATURES
1. MOVE LEVER TO RUN
1. MOVE LEVER TO RUN
2. ATTACH SLAVE POWER
2. ATTACH SLAVE POWER
SOURCE
SOURCE
3. PRESS LEVER A: THEN
3. PRESS LEVER A: THEN
a. ABOVE 23 F
a. ABOVE 23 F
(1) TURN START SWITCH
(1) TURN START SWITCH
TO START
TO START
b. AT 23FTO -5F
b. AT 23FTO -5 F
(1) PREHEAT FOR 1.5 MINUTES
(1) PREHEAT FOR 1.5 MINUTES
(2) TURN START SWITCH
(2) TURN START SWITCH
TO START
TO START
c. AT -5F TO -40 F
c. AT -5FTO -40 F
(1) ADD 2 mL OIL TO B
(1) ADD 2 mL OIL TO B
(2) MOVE AIR INTAKE TO COLD
(2) MOVE AIR INTAKE TO COLD
POSITION
POSITION
(3) PREHEAT FOR 3 MINUTES
(3) PREHEAT FOR 3 MINUTES
(4) TURN START SWITCH TO
(4) TURN START SWITCH TO
START PREHEAT
START PREHEAT
4. TURN LOAD CONTACTOR ON
4. TURN LOAD CONTACTOR ON
TO STOP
TO STOP
1. TURN LOAD CONTACTOR OFF
1. TURN LOAD CONTACTOR OFF
2. PRESS STOP LEVER
2. PRESS STOP LEVER
MEP-531A
MEP-501A
MEP-531A
MEP-501A
DETAIL A
DETAIL B
TEMP. -40F TO 0 F:
MIL-L-46167, 0W30
TEMP. 0F TO 120 F:
MIL-L-2104, 15W40
MIN. API TYPE: CC
DETAIL C
Figure 2-9. Identification and Instruction Plates (Sheet 2 of 2)
2-31