ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
Table 2-2. Operator Preventive Maintenance Checks and Services (Continued)
(1)
(2)
(3)
(4)
(5)
Interval
Item
Item To Be
Equipment Is Not
B
D
A
No.
Inspected
Procedure
Ready/Available If:
(7)
Inspect fuel system for loose or
Any fuel leaks, or damaged,
Fuel System
missing fuel line clamps,
loose, or missing parts.
damaged fuel lines, and
leaking/damaged fuel tank.
Check for evidence of fuels leaks.
Check fuel level and if necessary,
service fuel tank to red line on
fuel strainer. Ensure fuel tank fill
neck strainer is not clogged or
damaged.
The following fuels may be used
between 51 and 122F (-46 and
50C):
(a) DL-1 (A-A-52557) [-26 to
0F (-32 to -18C)]
(b) DL-2 (A-A-52557) [0 to
122F (-18 to 50C)]
(c) JP-8 (MIL-DTL-83133)
[-26F to -51F (-32C to
-46C)]