ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-80
(8)
Connect negative battery cable to battery, and close BATTERY ACCESS door (Figure 1-2).
4.8.2 Panel Lights DS1 through DS3.
a.
Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Remove directional cap (1, Figure 4-11) from panel light housing (5).
(3)
Remove light bulb (2) from panel light housing (5).
(4)
Set multimeter to ohms, and check light bulb for continuity across base and threads.
Multimeter should indicate continuity.
(5)
If multimeter does not indicate continuity, replace light bulb (2).
(6)
Inspect directional caps (1) for cracks, corrosions, stripped threads, and other damage.
(7)
Release DCS control panel by turning two fasteners, and lower panel slowly.
(8)
Inspect panel light housings (5) on DCS control panel (6) for cracks, corrosion, stripped
threads, and other damage.
(9)
Install light bulb (2) in panel light housing (5).
(10) Install directional cap (1) on panel light housing (5).
(11) Raise and secure DCS control panel.
(12) Remove DCS control box top panel, paragraph 4.7.2.
(13) Inspect panel light housing (5) on DCS control panel frame (7) for cracks, corrosion, stripped
threads, and other damage.
(14) Install DCS control box top panel, paragraph 4.7.2.
b. Repair.
(1)
Remove directional cap (1, Figure 4-11) from panel light housing (5).
(2)
Remove light bulb (2) from panel light housing (5).
(3)
Install light bulb (2) in panel light housing (5).
(4)
Install directional cap (1) in panel light housing (5).
c. Replacement.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.