ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-168
4.10.10 Coolant Recovery System.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open left side engine compartment access doors (Figure 1-2).
(3)
Inspect coolant recovery system components for cracks, holes, or other damage.
(4)
Replace damaged parts.
(5)
Close engine compartment access doors.
b. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open left side engine compartment access doors (Figure 1-2).
__________
WARNING
Cooling system operates at high temperature and pressure. Contact with high
pressure steam and/or liquids can result in burns and scalding. Shut down
generator set, and allow system to cool before performing checks, services, and
maintenance. Failure to comply can cause injury to personnel.
(3)
Loosen hose clamp (3, Figure 4-25). Disconnect hose (4) from overflow bottle (5), and drain
coolant into suitable container.
(4)
Loosen hose clamp (1), and disconnect hose (2) from overflow bottle (5).
(5)
Remove overflow bottle (5) from wire holder (10).
(6)
Remove nuts (6), lockwashers (7), washers, (8), bolts (9), and wire holder (10) from mounting
bracket (13).
(7)
Remove bolts (12), lockwashers (11), and mounting bracket (13) from engine.
c. Installation.
(1)
Install mounting bracket (13, Figure 4-25), lockwashers (11), and bolts (12) on engine.
(2)
Install wire holder (10), washers (8), bolts (9), lockwashers (7), and nuts (6) on mounting bracket
(13).
(3)
Install overflow bottle (5) in wire holder (10).
(4)
Position hose clamps (1 and 3) and hoses (2 and 4) on overflow bottle (5). Tighten hose clamps.
(5)
Fill overflow bottle (5) with coolant to the COLD level. Refer to Table 3-2 for proper coolant.