ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-120
FIGURE 4-16. DCS CONTROL BOX FLOOR COMPONENTS (SHEET 2 OF 2)
c. Replacement.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Remove DCS control box top panel, paragraph 4.7.2.
(4)
Tag and disconnect electrical leads from FREQUENCY SELECT switch (6, Figure 4-16).
(5)
Remove jamnut (4), lockwasher (5), and FREQUENCY SELECT switch (6) from auxiliary control
bracket (18).
(6)
Install FREQUENCY SELECT switch (6, Figure 4-16), lockwasher (5), and jamnut (4) on auxiliary
control bracket (18).
(7)
Connect electrical leads to FREQUENCY SELECT switch (6), and remove tags.
(8)
Install DCS control box top panel, paragraph 4.7.2.
(9)
Connect negative battery cable to battery, and close BATTERY ACCESS door.
4.8.28 REACTIVE CURRENT ADJUST Rheostat R5.