ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-117
(15) Install DCS control box top panel, paragraph 4.7.2.
(16) Connect negative battery cable to battery, and close BATTERY ACCESS door.
4.8.26 DC CONTROL POWER Fuse.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open DCS control panel.
(3)
Inspect DC CONTROL POWER fuseholder (3, Figure 4-16) for loose connections and mounting
hardware, cracked housing, and other damage.
(4)
Close DCS control panel.
b. Testing.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Release DCS Control Panel by turning two quick turn fasteners.
(3)
Remove cap (1, Figure 4-16) and fuse (2) from DC CONTROL POWER fuseholder (3) and remove
fuse from cap.
(4)
Set multimeter for ohms and connect across fuse ends. If fuse is good, multimeter will indicate
continuity.
(5)
If indications are not as above, replace fuse with one of identical size and rating.
(6)
Install good fuse (2) into cap and install cap (1) and fuse (2) into fuseholder (3).
(7)
Close DCS CONTROL PANEL and secure with two quick turn fasteners.
c. Replacement.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Remove DCS Control box top panel, paragraph 4.7.2
(4)
Tag and disconnect electrical leads from DC CONTROL POWER fuseholder (3, Figure 4-16).
(5)
Remove cap (1) and fuse (2) from fuseholder (3). Remove jamnut (24), which secures fuseholder to
auxiliary control bracket (18) and slide fuseholder thru auxiliary control bracket.
(6)
Install DC CONTROL POWER fuseholder (3, Figure 4-16), and secure with jamnut (24).
(7)
Connect electrical leads to DC CONTROL POWER fuseholder (3), and remove tags. Install cap (1)
and fuse (2), in fuseholder (3).