ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
3-19
(4)
Remove battery caps. (located on top of electrolyte type batteries).
CAUTION
Electrolyte level must cover battery plates in all cells. Failure to comply
can cause damage to battery.
NOTE
Electrolyte level should be at bottom of each cap cylinder.
(5)
Inspect electrolyte level.
(6)
Perform service procedure, step b below, if required.
(7)
Install battery caps.
(8)
Close BATTERY ACCESS door (Figure 1-2).
b. Service.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2).
__________
WARNING
Batteries give off a flammable gas. Do not smoke or use open flame when
performing maintenance. Failure to comply can cause injury or death to
personnel and equipment damage due to flames and explosion.
NOTE
Batteries used in the generator sets may be the maintenance-free type or the type
that contains electrolyte. If the batteries in your generator set are maintenance
free, skip steps (3) through (5), and go to step (6).
NOTE
Batteries used in the generator sets may be the maintenance-free type or the type
that contains electrolyte. If the batteries in your generator set are maintenance
free, skip steps (3) through (5) and go to step (6).
(3)
Remove battery caps .(located on top of electrolyte type batteries).