ARMY TM 9-6115-670-14&P
4-160
4.63. INDICATOR LAMPS.
This task covers:
Replace
INITIAL SETUP
Tools
General Mechanic's Tool Kit
(Item 1, Appendix B)
Shop Equipment, Electrical Repair,
Semitrailer Mounted
(Item 3, Appendix B)
Equipment Conditions
APU control unit disconnected from shelter.
Materials/Parts
Indicator Lamps
REPLACE
a. Remove ten screws (caged nuts (SICPS), machine screws (JTACS and WIN-T)) (1, Figure 4-51)
securing APU control unit front cover to chassis and remove cover.
b. At the rear of indicator light (3), identify and tag terminal leads (4).
c. Identify terminal lead at rear of indicator light leading to terminal lead at rear of ENGINE
START/PRE-HEAT switch.
d. Carefully cut away insulation sleeving and expose soldered connection. Desolder connection.
e. Identify second terminal lead at rear of indicator light connecting to terminal lead at APU connector.
f. Carefully cut away insulation sleeving and expose soldered connection. Use soldering iron to
unsolder connection.
g. At rear of indicator light, tuck in plastic wings (2) and gently pull indicator light (3) forward through
front panel.
NOTES
Terminal leads for indicator lamps in APU control units
configured for the SICPS system are installed into
terminal board TB1.
Refer to fold-out FO-1 (SICPS/WIN-T) or F0-7
(JTACS), then loosen appropriate screws in terminal
board TB1 to remove or install indicator lamp leads.
SICPS personnel may skip steps c through f, and i
through p.