ARMY TM 9-6115-670-14&P
4-96
a. Refer to Figure FO-1 (SICPS/WIN-T) or F0-7 (JTACS) and tag and remove connector lead AF (2)
from alternator.
b. Pull back protective cover and remove nut and washer (5) securing connector lead ALT (4) to
alternator (1). Tag and remove lead.
c. Remove bolt and lock washer (15) securing alternator to adjusting bracket (14).
d. Remove bolt (13), washer (12), spacer (10), breather tube brace (6), lock washer (8), and nut (7)
and remove alternator (1).
e. Remove fan belt (para 4.23.).
f. Align lower hole in alternator with hole in front mounting bracket (9) and install spacer (10).
g. Align washer (12) with hole in front mounting bracket (11) and insert bolt (13) through washer (12),
front mounting bracket (11), lower hole in alternator, spacer (10), and rear mounting bracket (9).
h. Install breather tube brace (6 and 1), lock washer (8), on bolt (13) and secure with nut (7).
i. Secure upper hole in alternator (1) to adjusting bracket (14) with bolt and lock washer (15).
j. Secure connector lead ALT (4) to alternator (1) and secure with washer and nut (5). Remove tag.
Install protective cover.
k. Secure connector lead AF (2) to alternator. Remove tag.
l. Install and adjust fan belt (para 4.23).
CAUTION
Take care not to cut wires or other APU components
when removing tiedown straps.
NOTE
Cut and remove tiedown straps as needed to remove
wiring harness.
NOTE
When removing, make note of tiedown strap locations.
Wiring harness will need to be secured at approximately
the same places.