e. Install new thermostat (4) in temperature sensor block (6).
f. Apply sealing compound to both sides of new gasket (7) and install thermostat housing on
temperature sensor block (6). Secure with gasket (7), two bolts and lock washers (9).
g. Install water hose (2) over thermostat housing (8) and tighten two clamps (1).
Figure 4-9. Thermostat