INTERVAL
TM 9-6115-653-14&P
Table 3-2. Operator/Crew Preventive Maintenance Checks and Services (PMCS) (cont).
B BEFORE
D DURING
A AFTER
W WEEKLY
M MONTHLY
B
D
A
W
M
24
BATTLE SHORT INDICATOR LIGHT
Push In on lens housing Light (32) should
Illuminate If not, replace bulb
25
CIRCUIT BREAKER INDICATOR LIGHT
Push in on lens housing Light (33) should
Illuminate If not, replace bulb
4885-021
26
BRAKE DRUMS AND HUBS
WARNING
A defect In the operation of the brakes or hub
can cause these parts to get hot enough to
cause serious burns Use extreme caution
when attempting to detect heat In this area
Feel drums and hubs for overheating
Brakes or hub are dragging
or binding
27
AIR RESERVOIR
Open draincock (34) to drain moisture from air
reservoir (35) and close when finished
ITEM
NO.
ITEM TO BE INSPECTED
PROCEDURE: CHECK FOR AND HAVE REPAIRED,
FILLED, OR ADJUSTED AS NEEDED
EQUIPMENT IS NOT
READY/AVAILABLE IF:
3-18