ARMY TM 9-6115-645-24
AIR FORCE TO 35C2-3-444-12
MARlNE CORPS TM 09244A/09245A-24/2
NOTES:
1. Dimensions shown are in inches.
2. Refer toTM 9-6115-645-24P for materials required.
PROCEDURES:
1. Strip 0.25 inch of insulation from end of each transducer (1) lead.
2. Crimp male terminal (2) on red wire and female terminal (3) on black wire.
FIGURE D-38. Transducer Assembly (P/N: 88-22550)
D-38