ARMY TM 9-6115-645-24
AIR FORCE TO 35C2-3-444-12
MARINE CORPS TM 09244A/09245A-24/2
f.
Connect resistance bridge and note readings between terminals T1 and T4, T2 and T5, T3 and T6, T7 and TO, T8
and TO, and T9 and TO of voltage reconnection terminal board.
g.
All resistance readings should be as shown in TABLE 4-3.
h.
If resistance is low, there are shorted windings, if resistance is high, stator windings are open. In either case,
stator must be replaced.
i.
Disconnect removable grounding link on load output terminal board (17, FIGURE 2-29).
j.
Set multimeter for ohms and connect between each coil lead and ground, in turn.
k.
If multimeter indicates resistance on any connection, stator windings are grounded and stator must be replaced.
I.
Connect removable grounding link on load output terminal board.
m. Connect wires 107C and 109J to terminals 1 and 2 of power potential transformer. Remove tags.
n.
Connect two electrical connectors to bottom of control box assembly.
o.
Install moveable terminal board and protective cover on voltage reconnection terminal board, paragraph 2-95.3.
p.
Connect negative battery cable and dose battery access door.
4-24.2. Removal.
a.
Shut down generator set.
b.
Remove generator assembly from generator set, paragraph 4-17.1.
c.
Remove generator rotor assembly, paragraph 4-23.2.
4-24.3. Installation.
a.
Install generator rotor assembly, paragraph 4-23.3.
b.
Install generator assembly in generator set, paragraph 4-17.2.
SECTION VII. MAINTENANCE OF SKID BASE
4-25
SKID BASE.
4-25.1. Removal.
a.
Shut down generator set.
b.
Remove engine and generator assembly, paragraph 3-6.1.
c.
Remove fuel tank, paragraph 4-7.2.
d.
Remove nuts (1, FIGURE 4-21), lockwashers (2), bolts (3), washers (4), and forklift guides (5) from skid base.
e.
Remove cable grommets (6) and (7) from skid base.
4-25.2. Repair.
Repair of the skid base will be limited to corrosion control and spot welding minor cracks. If major
structural damage to the skid base has occurred, replace the skid base.
4-25.3. Installation.
a.
Install forklift guides (5, FIGURE 4-21) in skid base with bolts (3), washers (4), lockwashers (2), and nuts (1).
b.
Install cable grommets (6) and (7) in skid base.
c.
Install fuel tank, paragraph 4-7.3.
d.
Install engine and generator assembly, paragraph 3-6.2.
SECTION VIII. MAINTENANCE OF LUBRICATION SYSTEM
4-26
OIL DRAIN LINE.
For removal and installation of oil drain line, refer to paragraph 3-7.
4-42. Change 2