ARMY TM 9-6115-644-24
AIR FORCE TO 35C2-3-446-12
MARINE CORPS TM 09249A/09246A-24/2
m. Install rear housing panel, paraqraph 2-18-4.
n.
Install control box assembly, paragraph 2-19-4.
o.
Install output box access door, paragraph 2-14-4.
p. Connect negative battery cable and dose battery access door.
4-9 VOLTAGE RECONNECTION TERMINAL BOARD.
4-9-1 Removal
a.
b.
c.
d.
e.
f.
g.
h.
i.
Shut down generator set.
Open battery access door and disconnect negative battery cable.
Open output box access door and load terminal board access door.
Remove nuts (8, FIGURE 4-5), washers (9), and cover (10) from voltage reconnection board (18).
Unscrew standoffs (11) and remove washers (12), bolts (13), washers (14), and mounts (15).
Remove nuts (16), tag and disconnect electrical cables (17) and main generator cables from voltage reconnec-
tion board (18).
Remove voltage reconnection board (18) and moveable terminal board (20) from generator set as assembly.
Tag position of capacitors (22) on voltage reconnection board (18).
Remove nuts (19), moveable terminal board (20), studs (21), and capacitors (22) from voltage reconnection
board (18).
4-9-2 Installation.
a.
Insert studs (21, FIGURE 4-5) in voltage reconnection board (18). Position capacitors (22) as tagged, align
moveable terminal board (20) with voltage reconnection board (18) and install nuts (19). Remove tags.
b. Position voltage reconnection board (18) and moveable terminal board (20) in generator set.
c.
Connect electrical cables (17) and main generator cables to voltage reconnection board (18) with nuts (16) and
remove tags.
d. Secure voltage reconnection board (18) to generator set with bolts (13), washers (14), mounts (15), washers
(12), and standoffs (11).
e.
Install cover (10) with washers (9) and nuts (8).
f.
Close output box and load terminal board access doors.
g.
Connect negative battery cable and dose battery access door.
4-10 OUTPUT BOX HARNESS.
4-10-1 Inspection.
a. Remove output box harness, paragraph 4-10-2.
b. Inspect wiring harness for burned, bent, corroded, and broken terminals.
4-19