Close output box access door.
Connect negative battery cable and close battery access door.
Removal.
Shut down generator set.
Open battery access door and disconnect negative battery cable.
Open output box and right side engine access doors.
Tag and disconnect cranking relay (17, FIGURE 2-28) electrical leads.
Remove screws (16), nuts (15), and cranking relay (17) from output box.
Install cranking relay (17, FIGURE 2-28) with screws (16) and nuts (15).
Connect electrical leads and remove tags.
Close output box and right side engine access doors.
Connect negative battery cable. Close battery access door.
Installation
2-103 LOAD OUTPUT TERMINAL BOARD.
2-103-1
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
k.
R e m o v a l .
Shut down generator set.
Open battery access door and disconnect negative battery cable.
Open load terminal board access door and disconnect load output cables L1, L2, L3, and L0 from load output
terminal board
Remove generator set housing rear panel, paragraph 2-18-1.
Remove bolt (1, FIGURE 2-29), nut (2), flatwasher (3), and Iockwasher (4) securing ground strap (15) to skid
b a s e .
Remove bolts (5), Iockwashers (6), and washers (7) securing terminal board assembly (12) to supports.
Remove nuts (8) and washers (9), tag and disconnect all main power leads (10) and varistor Ieads (11) from
load terminals (23).
Remove terminal board assembly (12) from generator set.
Remove load output terminals, paragraph 2-104-1.
Remove EMI filter (24) positioned between LO and GND terminals (23).
Remove varistor leads (11) from varistors (27).