ARMY TM 9-6115-643-24
AIR FORCE TO 35C2-3-445-22
d. Ensure that inside diameter of exhaust pipe extension is as large or larger than generator exhaust pipe.
Hot exhaust gases can ignite flammable materials. Failure to observe
this warning could result in severe personal injury or death.
e. Provide for harmless discharge of hot gases and sparks. Do not direct exhaust into area containing flammable ma-
terials.
WARNING
If not shielded, hot exhaust pipe can ignite flammable wall materials.
Failure to observe this warning could result in severe personal injury or
death.
f. Shield exhaust pipe with fireproof material at point where it passes through a flammable wall.
An unwrapped exhaust pipe can cause injury if touched,
g. Wrap exhaust pipe in protective material.
h. Allow space on all sides for service and maintenance. Refer to FIGURE 22 for minimum clearance measurements.
2.3.
FABRICATION/ASSEMBLY OF PARTS.
TABLE 24 is a list of generator set parts that require fabrication or assembly when replacing. See Appendix D for
fabrication and assembly instructions.
2-7