Fill engine with proper engine lubricating oil in accordance with TABLE 2-3 to FULL mark on dipstick. Lubrication
system capacity is 6 quarts (5.7 Iiters).
Install oil fill cap.
Close battery access door.
TABLE 2-2. Fuel
AMBlENT TEMPERATURE
DIESEL FUEL
+20°F TO +120°F
VV-F-800 GRADE DF-2,
(-6°C TO 49°C)
JP4, JP5, OR JP8
0°F TO +20°F
VV-F-800 GRADE DF-1,
(-17°C TO -6°C)
JP4, JP5, OR JP8
25°F TO 0°F
VV-F-800
(-32°C TO -17°C)
GRADE DF-1
-25°F TO 0°F
VV-F-800
(-32°C TO -17°C)
GRADE DF-A
TABLE 2-3. Lubricating Oil
AMBlENT TEMPERATURE
LUBRICATING OIL
+20°F TO +120°F
MIL-L-2104
(-6°C TO 49°C)
OE HDO-30 or
OE HDO-15/40
0°F TO +20°F
MIL-L-2104
(-17°C TO 6°C)
OE HDO-10
-25°F TO 0°F
MIL-L-46167
(-32°C TO -17°C)
GENERATOR SET INSTALLATION.
General
WARNING
Do not operate generator set in an enclosed area unless exhaust fumes
are piped outside the enclosure. Exhaust gases contain noxious and
deadly fumes. Failure to observe this warning could result in severe per-
sonal injury or death.
a. Ensure that installation site is as level as possible.
b. Provide adequate ventilation to prevent recirculation of hot air exhausted from generator set.
c. Refer to FIGURE 2-1 for base mounting measurements.
2.2.2.
Outdoor Installation.
a. Make use of natural protective barriers.
b. Allow space on all sides for service and maintenance. Refer to FIGURE 22 for minimum clearance measurements.
c. Ensure that site soil is firm and well drained.
d. Use planks or other material for support in areas where soil will not support the generator set.