ARMY TM 9-6115-643-24
AIR FORCE TO 35C2-3-445-22
f.
Unsolder electrical lead (6, FIGURE 4-9) from diode (7) being removed.
g.
Press diode (7) from diode mounting plate assembly (5).
4.17.3 Installation.
a.
b.
c.
d.
e.
f.
g.
Run bead of thermal-electric compound (Item 8, Appendix C) around base of diode (7, FIGURE 4-9) prior to instal-
ling.
Press diode (7) into diode mounting plate assembly (5).
Using solder (Item 17, Appendix C) and soldering iron, solder electrical lead (6) to diode (7).
Install rotating rectifier, paragraph 4.19.2.
Install generator end bell, paragraph 4.18.2.
Install generator set housing rear panel, paragraph 2.18.4.
Connect negative battery cable and close battery access door.
FIGURE 4-9. Rectifier Assembly (MEP-804A)
Change 4
4-33