ARMY TM 9-6115-643-24
AIR FORCE TO 35C2-3-445-22
FIGURE 2-25. Fan Belt
e. Close engine access doors.
f.
Connect negative battery cable and close battery access door.
2.84.
COOLANT RECOVERY SYSTEM.
2.84.1.
Inspection.
a. Shut down generator set.
b. Open left side engine access door.
c.
Inspect coolant recovery system components for cracks, holes, or other damage
d. Close left side engine access door.
2 .8 4 . 2 . Removal.
a. Shut down generator set.
b. Open left side engine access door.
Coolant can get very hot. Allow system to cool down before performing
maintenance. Failure to follow these instructions could result in severe
burns and injuries.
c.
Loosen clamp (1, FIGURE 2-26) and disconnect hose (2) from overflow bottle (5) and drain coolant into suitable
container.
d. Loosen clamp (3) and disconnect hose (4) from overflow bottle (5).
2-123