ARMY TM 9-6115-643-24
AIR FORCE TO 35C2-3-445-22
2.44.4.
Installation.
a. Position FREQUENCY SELECT switch (14, FIGURE 2-14) in mounting bracket
b. Install lockwasher (13) and nut (12).
c.
Install resistor (11) on FREQUENCY SELECT switch (14) and remove tags.
d. Connect electrical leads and remove tags.
e. Install control box top panel, paragraph 2.15.4.
f.
Connect negative battery cable and close battery access door.
2.45.
CONVENIENCE RECEPTACLE.
2.45.1.
Inspection.
a. Shut down generator set.
b.
Inspect CONVENIENCE RECEPTACLE for cracks, breaks, corrosion, bent terminals, or other indications of darn-
age.
c.
Inspect cover for cracks, corrosion, or damaged springs.
d. Replace defective pans.
2.45.2.
Testing.
a. Shut down generator set.
b. Remove control box top panel, paragraph 2.15.1.
c. Tag and disconnect CONVENIENCE RECEPTACLE (20, FIGURE 2-14) electrical leads.
d.
Set multimeter for ohms and check for continuity between upper side terminals and lower side terminals of each
plug outlet.
e. Replace CONVENIENCE RECEPTACLE if continuity is indicated between terminals.
f.
Connect electrical leads to receptacle (20) and remove tags.
g. Install control box top panel, paragraph 2.15.4.
2.45.3.
Removal.
a. Shut down generator set.
b. Open battery access door and disconnect negative battery cable.
c.
Remove control box top panel, paragraph 2.15.1.
d. Remove screws (15, FIGURE 2-14) and nuts (16).
e. Remove CONVENIENCE RECEPTACLE cover (17).
f.
Remove machine screws (18), nuts (19), and CONVENIENCE RECEPTACLE (20).
g. Tag and disconnect CONVENIENCE RECEPTACLE (20) electrical leads.
2.45.4.
Installation.
a. Connect electrical leads to CONVENIENCE RECEPTACLE (20, FIGURE 2-14) and remove tags.
b. Install CONVENIENCE RECEPTACLE (20) into panel cutout with machine screws (18) and nuts (19).
2-77