ARMY TM 9-6115-643-10
AIR FORCE TO 35C2-3-445-21
SECTION II.
EQUIPMENT DESCRIPTION
1-6
EOUIPMENT CHARACTERISTICS,
1-7.2 Radiator (22). The
CAPABILITIES AND FEATURES.
radiator is located at the front
The generator sets, models
as a heat exchanger for the
engine coolant.
1-2), are fully enclosed, self-
contained, skid-mounted,
portable units. They are
to the exhaust manifold on the
equipped with controls,
instruments and accessories
necessary for operation as
the top of the generator set
housing. Gases are exhausted
single units or in parallel with
another unit of the same class
upward.
1-7.4 Starter (14) . The
consist of a diesel engine,
brushless generator, excitation
starter is located on the left
side of the engine. The
system, speed governing system,
fuel system, 24 VDC starting
electric starter mechanically
system, control system and fault
engages the engine flywheel in
system.
order to start the diesel
engine.
NOTE
1-7.5 Battery Charginq
All locations refer-
on the left side of the engine.
are given facing the
It is capable of maintaining the
control panel assembly
(rear) of the genera-
batteries in a state of full
tor set.
charge in addition to providing
the required 24 VDC control
1-7 LOCATION AND DESCRIPTION OF
power.
MAJOR COMPONENTS.
1-7.6 Batteries (23) . Two
1-7.1 Engine (16). The
batteries are located at front
generator is powered by a four
cylinder, four cycle, fuel
batteries are electrolyte
injected, naturally aspirated,
serviceable, lead acid, 12 volt
liquid-cooled diesel engine
type, connected in series.
which occupies the front half of
After starting, the generator
set is capable of operating with
is also equipped with a fuel
batteries removed. A diode and
filter/water separator, oil
a fuse, located behind the
filter, and an air cleaner
control panel assembly, protect
assembly. Protection devices
the generator set if the
automatically stop the engine
batteries are incorrectly
during conditions of high
connected.
coolant temperature, low oil
pressure, no fuel, over-speed,
or over-voltage.