ARMY TM 9-6115-642-24
AIR FORCE TO 3562-3-455-12
MARINE CORPS TM 09247A/09248A-24/2
2-36.2
a.
b.
C.
d.
e.
f.
g.
2-36.3
a.
b.
C.
d.
Removal.
Shut down generator set.
Open left side engine access door and disconnect negative battery cable.
Remove control box top panel, paragraph 2-16.1.
Loosen rear outer ring and plastic insert from diagnostic connector (47, FIGURE 2-11).
Tag and disconnect electrical leads from diagnostic connector (47) by inserting removal tool into pins of connector.
Remove screws (43) and nuts (44).
Remove diagnostic connector (47), gasket (46), and cap (45).
Installation.
Install diagnostic connector (47, FIGURE 2-11), gasket (46), and cap (45) with screws (43) and nuts (44).
Connect electrical leads and remove tags.
Install control box top panel, paragraph 2-16.4.
Connect negative battery cable and close access door
FIGURE 2-13. Diagnostic Connector Pin Positions
Change 2
2-63