TABLE 3-1. Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
5.
6.
Step 2.
Check to see if any FAULT INDICATOR lights are lit.
NO FUEL light is lit. refer to paragraph 3-3.5.1. If any other lights are lit, notify next higher maintenance
level.
Engine stops suddenly.
Step 1.
Check to see if any FAULT INDICATOR lights are lit.
NO FUEL light is lit, refer to paragraph 3-3.5.1. If any other lights are lit, go to step 2.
Step 2.
Check that DC CONTROL POWER circuit broker is energized (in).
If DC CONTROL POWER circuit breaker is deenergized (out), notify next higher maintenance level.
Engine runs erratically or misfires.
Step 1.
Check for dirty air cleaner element.
Service air cleaner assembly. refer to paragraph 3-3.3.2.
Step 2.
Check far contaminated fuel.
Service fuel filter/water separator, refer to paragraph 3-3.6.2.
Step 3.
Check for improper type of fuel.
If improper fuel is suspected, refer to TABLE 3-3, notify next higher maintenance level.
Engine does not develop full power.
Step 1.
Check for dirty air clearer element.
Service air cleaner assembly, refer to paragraph 3-3.3.2.
Step 2.
Check for contaminated fuel.
Service fuel filter/water separator, refer to paragraph 3-3.6.2.
3-4