ARMY TM 9-6115-641-24
AIR FORCE TO 35 C2-3-456-12
Section IV. MAINTENANCE OF COOLANT SYSTEM
4-6. RADIATOR REPAIR.
Repair radiator in accordance with TM 750-254.
Section V. MAINTENANCE OF ENGINE ACCESSORIES
4-7. ADJUSTING FREQUENCY DROOP AT ENGINE GOVERNOR.
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
NOTE
Frequency droop should be checked whenever maintenance has been performed on the
engine governor, or the engine assembly has been replaced. Adjust frequency droop as
follows if droop does not meet the performance characteristics listed in Table 1-2.
Shut down generator set.
Open left side engine access door and disconnect negative battery cable.
Remove left side fan guard, paragraph 2701.
Remove plug (1, Figure 4-13) from engine governor housing (3).
NOTE
Do not turn adjustment screw more than one turn at a time.
Using a 5 mm hex key, at least 5 in. long, adjust screw (2) clockwise to decrease the amount of droop.
Install plug (1), connect negative battery cable and close left side engine access door.
Start generator set and check frequency droop.
Shut down generator set.
Repeat procedures until frequency droop meets performance characteristics listed in Table 12.
Open left side engine access door, install left fan guard, paragraph 2705, and close left side engine access
door.
4-16