ARMY TM 9-6115-639-13
AIR FORCE TO 35C2-3-386-51
MARINE CORPS TM 10155A-13/1
4-48. COOLING FAN AND TEMPERATURE SWITCH MAINTENANCE - cont.
5.
Mate high temperature switch S20 (17, Figure 4-42) (110 F) to rear wall of enclosure and secure using
two screws (14), lockwashers (15), and washers (16). Connect two electrical wires (18, 19) to temperature
switch.
6.
Mate high temperature fan (2) to rear wall of enclosure and secure using two screws (8), lockwashers (9),
and washers (10). Left hand screw (8) secures electrical wire (7).
7.
Connect fan power cord (6) to generator set wiring harness. Connect wire (7) to fan using screw (11),
lockwasher (12), and washer (13).
8.
Install finger guard (1) onto fan (2) using two screws (3), washers (4), and nuts (5).
9.
Close main access cover and lock in place using latches.
4-118