d.
Remove the fuel filter bowl, and pour out the fuel from the bowl; reinstall the
bowl.
Disconnect the tank-to-pump fuel supply line at the boost pump. Connect a
e.
flexible line to the pump, and place the open end of the line in a one-gallon-
capacity container filled with lubricating oil, Military Specification MIL-O-6081,
Grade 1010.
Disconnect the flexible fuel supply line from the dummy fitting. Place the open
f.
end of the flexible line in a suitable waste fuel container.
g.
Move START-RUN-OFF switch to RUN.
h.
Move BOOST PUMP switch to BOOST PUMP. The boost pump will operate and
i.
Move BOOST PUMP switch to OFF when preservative oil flows out the flexible
j.
line.
Move START-RUN-OFF switch to OFF.
k.
Pull DC CONTROL circuit breaker.
l.
m. Reconnect the flexible fuel supply line to the dummy fitting.
n.
Disconnect the flexible line from the boost pump, and reconnect the tank-to-
pump fuel supply line.
o.
Remove the fuel tank drain fitting and drain all the preservative oil from the
tank. Reinstall the drain fitting.
Wipe any spilled oil from the stand surface and from stand components.
p.
2-11. PREPARATION FOR STORAGE.
2-12. The check stand must be prepared for storage, as follows:
Perform fuel system preservation in accordance with instructions in
a.
b.
Disconnect the power cable from the battery.
2-4